User feedback can only catch the single side of the message after the 12508 configuration of the local mirror both, so it suspects the equipment failure
Check the configuration and find the port mirroring configuration is configured properly:
mirroring-group 2 local
interface GigabitEthernet1/6/0/32
port link-mode bridge
mirroring-group 2 monitor-port
# interface Ten-GigabitEthernet1/4/0/18
port link-mode bridge
port link-type trunk
undo port trunk permit vlan 1
port trunk permit vlan 114 4019
qos apply policy SW-02 inbound
mirroring-group 2 mirroring-port both
But it turns out that in addition to the local mirroring configuration, the device is configured with a flow mirroring as follows:
traffic classifier SW-02 operator
and if-match acl 3334
traffic behavior SW-02
mirror-to vlan 500
qos policy SW-02
classifier SW-02 behavior SW-02
The engineer consulted the manual and found the following limitations on the device. When the local mirroring and flow mirroring are configured at the same time, only the flow mirroring will take effect.
Remove the flow mirroring configuration to make the local mirroring take effect.