==== display fan ====
Chassis 1: Fan Frame 1 State: Normal
Fan Frame 2 State: Normal
Chassis 2: Fan Frame 1 State: Normal
Fan Frame 2 State: Normal
2、The device temperature is normal, but the temperature of two slots is relatively high, which causes the fan speed to increase.
==== display envirOnment====
System temperature information (degree centigrade):
----------------------------------------------------------------------
Chassis Slot Sensor Temperature Lower Warning Alarm Shutdown
1 0 inflow 1 25 0 78 92 NA
1 0 outflow 1 27 0 78 92 NA
1 0 hotspot 1 40 0 85 92 NA
1 1 inflow 1 22 0 78 92 NA
1 1 outflow 1 23 0 78 92 NA
1 1 hotspot 1 37 0 85 92 NA
1 2 outflow 1 21 0 78 92 NA
1 2 hotspot 1 26 0 85 92 NA
1 2 hotspot 2 31 0 88 102 107
1 2 hotspot 3 32 0 88 102 107
1 10 outflow 1 43 0 78 92 NA
1 10 hotspot 1 45 0 92 106 NA
1 10 hotspot 2 50 0 88 102 107
1 11 outflow 1 41 0 78 92 NA
1 11 hotspot 1 41 0 92 106 NA
1 11 hotspot 2 48 0 88 102 107
1 12 outflow 1 43 0 78 92 NA
1 12 hotspot 1 41 0 92 106 NA
1 12 hotspot 2 51 0 88 102 107
1 13 outflow 1 57 0 78 92 NA
1 13 hotspot 1 43 0 92 106 NA
1 13 hotspot 2 74 0 88 102 107
2 0 inflow 1 24 0 78 92 NA
2 0 outflow 1 25 0 78 92 NA
2 0 hotspot 1 39 0 85 92 NA
2 1 inflow 1 22 0 78 92 NA
2 1 outflow 1 22 0 78 92 NA
2 1 hotspot 1 39 0 85 92 NA
2 2 outflow 1 21 0 78 92 NA
2 2 hotspot 1 26 0 85 92 NA
2 2 hotspot 2 32 0 88 102 107
2 2 hotspot 3 31 0 88 102 107
2 10 outflow 1 43 0 78 92 NA
2 10 hotspot 1 43 0 92 106 NA
2 10 hotspot 2 52 0 88 102 107
2 11 outflow 1 40 0 78 92 NA
2 11 hotspot 1 41 0 92 106 NA
2 11 hotspot 2 49 0 88 102 107
2 12 outflow 1 43 0 78 92 NA
2 12 hotspot 1 42 0 92 106 NA
2 12 hotspot 2 52 0 88 102 107
2 13 outflow 1 56 0 78 92 NA
2 13 hotspot 1 43 0 92 106 NA
2 13 hotspot 2 73 0 88 102 107
3、A safety panel is not installed in slot 14 and slot 15. As a result, the air channel is blocked, which affects the heat dissipation of the network module and causes the fan speed to be high.
===============display device verbose===============
Slot Type State Subslot Soft Ver Patch Ver
1/0 LSXM2SUPT2 Master 0 S12500G-AF-7624P10 None
1/1 LSXM2SUPT2 Standby 0 S12500G-AF-7624P10 None
1/2 LSXM1QGS36TD2 Normal 0 S12500G-AF-7624P10 None
1/3 NONE Absent 0 NONE None
1/4 NONE Absent 0 NONE None
1/5 NONE Absent 0 NONE None
1/6 NONE Absent 0 NONE None
1/7 NONE Absent 0 NONE None
1/8 NONE Absent 0 NONE None
1/9 NONE Absent 0 NONE None
1/10 LSXM2SFT08E2 Normal 0 S12500G-AF-7624P10 None
1/11 LSXM2SFT08E2 Normal 0 S12500G-AF-7624P10 None
1/12 LSXM2SFT08E2 Normal 0 S12500G-AF-7624P10 None
1/13 LSXM2SFT08E2 Normal 0 S12500G-AF-7624P10 None
1/14 NONE Absent 0 NONE None
1/15 NONE Absent 0 NONE None
If there are any equipment fan noise is big, can view the equipment state of fan and temperature is normal, when temperature is normal, to see whether there is a specific slot compared to other slot temperature is an obvious difference, if there is obvious difference, need to see if the corresponding slot screen is in use, if the slot does not use need to check whether installed security panel. If the sFU slots are not in use, install filler panels. If no filler panel is installed, the air channel is blocked, which affects the heat dissipation of the network board and causes the fan speed to be high.
If some slot is not in use, install filler panels in the corresponding slot. If no filler panel is installed, the air channel is blocked, which affects the heat dissipation of the network board and causes the fan speed to be high.