The fan of the S12508G is noisy

2022-03-03 15:14:45 Published
  • 0Followed
  • -1Collected ,507Browsed
MengPu 4level
fans:0 follow:0

Network Topology

Null

Problem Description

The fan of the S12508G is noisy  

Process Analysis

1、Check whether the fan status is normal.  

   ==== display fan ==== 

 Chassis 1: Fan Frame 1 State: Normal 

                 Fan Frame 2 State: Normal 

 Chassis 2: Fan Frame 1 State: Normal 

                 Fan Frame 2 State: Normal


 2、The device temperature is normal, but the temperature of two slots is relatively high, which causes the fan speed to increase.

==== display envirOnment==== 

 System temperature information (degree centigrade):

----------------------------------------------------------------------

Chassis  Slot  Sensor    Temperature  Lower  Warning  Alarm  Shutdown

1        0     inflow  1 25           0      78       92     NA     

 1        0     outflow 1 27           0      78       92     NA     

 1        0     hotspot 1 40           0      85       92     NA     

 1        1     inflow  1 22           0      78       92     NA     

 1        1     outflow 1 23           0      78       92     NA     

 1        1     hotspot 1 37           0      85       92     NA     

 1        2     outflow 1 21           0      78       92     NA     

 1        2     hotspot 1 26           0      85       92     NA     

 1        2     hotspot 2 31           0      88       102    107    

 1        2     hotspot 3 32           0      88       102    107    

 1        10    outflow 1 43           0      78       92     NA     

 1        10    hotspot 1 45           0      92       106    NA     

 1        10    hotspot 2 50           0      88       102    107    

 1        11    outflow 1 41           0      78       92     NA     

 1        11    hotspot 1 41           0      92       106    NA     

 1        11    hotspot 2 48           0      88       102    107    

 1        12    outflow 1 43           0      78       92     NA     

 1        12    hotspot 1 41           0      92       106    NA     

 1        12    hotspot 2 51           0      88       102    107    

 1        13    outflow 1 57           0      78       92     NA     

 1        13    hotspot 1 43           0      92       106    NA     

 1        13    hotspot 2 74           0      88       102    107       

2        0     inflow  1 24           0      78       92     NA     

 2        0     outflow 1 25           0      78       92     NA     

 2        0     hotspot 1 39           0      85       92     NA     

 2        1     inflow  1 22           0      78       92     NA     

 2        1     outflow 1 22           0      78       92     NA     

 2        1     hotspot 1 39           0      85       92     NA     

 2        2     outflow 1 21           0      78       92     NA     

 2        2     hotspot 1 26           0      85       92     NA     

 2        2     hotspot 2 32           0      88       102    107    

 2        2     hotspot 3 31           0      88       102    107    

 2        10    outflow 1 43           0      78       92     NA     

 2        10    hotspot 1 43           0      92       106    NA     

 2        10    hotspot 2 52           0      88       102    107    

 2        11    outflow 1 40           0      78       92     NA     

 2        11    hotspot 1 41           0      92       106    NA     

 2        11    hotspot 2 49           0      88       102    107    

 2        12    outflow 1 43           0      78       92     NA     

 2        12    hotspot 1 42           0      92       106    NA     

 2        12    hotspot 2 52           0      88       102    107    

 2        13    outflow 1 56           0      78       92     NA     

 2        13    hotspot 1 43           0      92       106    NA     

 2        13    hotspot 2 73           0      88       102    107     


3、A safety panel is not installed in slot 14 and slot 15. As a result, the air channel is blocked, which affects the heat dissipation of the network module and causes the fan speed to be high.

===============display device verbose=============== 

Slot   Type                  State    Subslot  Soft Ver            Patch Ver

1/0    LSXM2SUPT2            Master   0        S12500G-AF-7624P10  None     

1/1    LSXM2SUPT2            Standby  0        S12500G-AF-7624P10  None     

1/2    LSXM1QGS36TD2         Normal   0        S12500G-AF-7624P10  None     

1/3    NONE                  Absent   0        NONE                None     

1/4    NONE                  Absent   0        NONE                None     

1/5    NONE                  Absent   0        NONE                None     

1/6    NONE                  Absent   0        NONE                None     

1/7    NONE                  Absent   0        NONE                None     

1/8    NONE                  Absent   0        NONE                None     

1/9    NONE                  Absent   0        NONE                None     

1/10   LSXM2SFT08E2          Normal   0        S12500G-AF-7624P10  None     

1/11   LSXM2SFT08E2          Normal   0        S12500G-AF-7624P10  None     

1/12   LSXM2SFT08E2          Normal   0        S12500G-AF-7624P10  None     

1/13   LSXM2SFT08E2          Normal   0        S12500G-AF-7624P10  None     

1/14   NONE                  Absent   0        NONE                None     

1/15   NONE                  Absent   0        NONE                None      

Solution

If there are any equipment fan noise is big, can view the equipment state of fan and temperature is normal, when temperature is normal, to see whether there is a specific slot compared to other slot temperature is an obvious difference, if there is obvious difference, need to see if the corresponding slot screen is in use, if the slot does not use need to check whether installed security panel. If the sFU slots are not in use, install filler panels. If no filler panel is installed, the air channel is blocked, which affects the heat dissipation of the network board and causes the fan speed to be high.

If some slot is not in use, install filler panels in the corresponding slot. If no filler panel is installed, the air channel is blocked, which affects the heat dissipation of the network board and causes the fan speed to be high.

Please rate this case:   
0 comments

No comments

Add Comments:

举报

×

侵犯我的权益 >
对根叔知了社区有害的内容 >
辱骂、歧视、挑衅等(不友善)

侵犯我的权益

×

泄露了我的隐私 >
侵犯了我企业的权益 >
抄袭了我的内容 >
诽谤我 >
辱骂、歧视、挑衅等(不友善)
骚扰我

泄露了我的隐私

×

您好,当您发现根叔知了上有泄漏您隐私的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您认为哪些内容泄露了您的隐私?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)

侵犯了我企业的权益

×

您好,当您发现根叔知了上有关于您企业的造谣与诽谤、商业侵权等内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到 zhiliao@h3c.com 邮箱,我们会在审核后尽快给您答复。
  • 1. 您举报的内容是什么?(请在邮件中列出您举报的内容和链接地址)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
  • 3. 是哪家企业?(营业执照,单位登记证明等证件)
  • 4. 您与该企业的关系是?(您是企业法人或被授权人,需提供企业委托授权书)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

抄袭了我的内容

×

原文链接或出处

诽谤我

×

您好,当您发现根叔知了上有诽谤您的内容时,您可以向根叔知了进行举报。 请您把以下内容通过邮件发送到zhiliao@h3c.com 邮箱,我们会尽快处理。
  • 1. 您举报的内容以及侵犯了您什么权益?(请在邮件中列出您举报的内容、链接地址,并给出简短的说明)
  • 2. 您是谁?(身份证明材料,可以是身份证或护照等证件)
我们认为知名企业应该坦然接受公众讨论,对于答案中不准确的部分,我们欢迎您以正式或非正式身份在根叔知了上进行澄清。

对根叔知了社区有害的内容

×

垃圾广告信息
色情、暴力、血腥等违反法律法规的内容
政治敏感
不规范转载 >
辱骂、歧视、挑衅等(不友善)
骚扰我
诱导投票

不规范转载

×

举报说明

提出建议

    +

Login before you can operate!

login

你的邮箱还未认证,请认证邮箱或绑定手机后进行当前操作