Some terminals do not work after the main/backup switch

2023-06-30 22:25:04 Published
  • 0 Followed
  • 0Collected ,624Browsed

Network Topology

null

Problem Description

Some terminals do not work after the main/backup switch

Process Analysis

 Before the E2450P01 (not included) version of WA6600 series AP, there was a problem that the terminal did not work when the main and backup dual-link switchover occurred, specifically, when the main and backup AC switchover occurred, some terminals showed that the SSID remained connected, but the terminal could not ping the gateway and the external network, and it was necessary to manually disconnect the wifi switch and re-access the SSID to restore normal.

Solution

Upgrade the version to E2450P01 or above to solve the problem.

Please rate this case:   