The AC of a site is
degraded and prompts that the decompression of the AP file fails.
The on-site AC model is WX2560H, the current version is R5430P04, and I want to roll back to R5272, but the rollback version keeps prompting that the decompression of the AP file fails, and the error message shows " Failed to decompress file AP.ipe ". That's right. It has been confirmed by research and development that the packaging method of AP has changed since version 5421, so this error will be displayed, but don’t worry, after restarting, the version AC that rolls back to 5272 will decompress the IPE file of AP again, so it will not be affected. Involved models: WX3508H and lower end (for example: WX2500H series on site) AC involved.
No special processing is required, just restart the boot-loader directly, and the AC will still decompress the AP 's IPE file after restarting.