Mesh and rrm automatic bandwidth adjustment cannot be configured at the same time

2023-07-01 06:06:37 Published
  • 0 Followed
  • 0Collected ,912Browsed

Problem Description

 Mesh and rrm automatic bandwidth adjustment cannot be configured at the same time

Solution

When the rrm automatic bandwidth is enabled, the temporary link in the zero-configuration mesh environment can be established normally, and the ap can go online to the ac. After the official link is established, as long as the ap goes online to the ac, it will find that the bandwidth adjusted by rrm is inconsistent, causing the mesh link to be broken. open.

Workaround: Manually configure the bandwidth of the AP or turn off rrm automatic bandwidth.