iMC PLAT 7.3 E0708
iMC WSM 7.3 E0612P04
After the customer configured the AP Bandwidth instance, the trend records in the report cannot be observed.
Check if the component is correctly deployed ------ Wireless Pref Collect Engin is correctly deployed.
After R&D confirmation, it is a known issue for the version and has been resolved in WSM E0613 or E0614.
Solution:
Upgrade WSM component to E0613 or E0614.
Workaround:
Modify the configuration file, and then restart the imcwlanperfdm backend. Add the configuration item "RestartWeekDay=10" at the end of the configuration file iMC\server\conf\imc_wsm_perf.conf.
After operating on-site according to the workaround, the problem was immediately resolved.