Technical announcement on incorrect IP address on the nameplates of FW F100-C and F1000-AI

2024-02-04 14:20:41 Published
  • 0 Followed
  • 0Collected ,1526Browsed

Product Model

Announcement category

Early warning

Operational requirements

Learning prevention

I.        Product Model

NS-SecPath F1000-AI-10

NS-SecPath F1000-AI-15

NS-SecPath F100-C-A2-I

NS-SecPath F100-C-A1-I


Involved Version

ALL

Problem Description

The nameplates of F100-C-A1,F100-C-A2, F1000-AI-10, and F1000-AI-15 identify the default login IP address, which is 198.168.0.1/24. However, this address is incorrect, and the correct default login IP address should be 192.168.0.1/24. 


Cause Analysis

This is a typo, the address marked on the nameplate is different with the value set by the software. To achieve successful login, 192.168.0.1 must be used.

Workaround/Solutions

Workaround:

To achieve successful login, 192.168.0.1 must be used.

Solution:

Devices shipped since January 27, 2024 have corrected this typo.


Please rate this case:   