Unified Platform setup for forwarding only emergency and important alarms still receives notification-level alarms experience case

2025-02-13 14:36:32 Published
  • 0 Followed
  • 0Collected ,2Browsed

Problem Description

As shown in the figure below, the alarm forwarding rule is set to only focus on alarms of critical and major levels

but still receive interface up notifications at the alarm level



 


Process Analysis

The received notification-level alarm is an interface up alarm, and others are also clear alarms. Checking the alarm parameter settings reveals that automatic forwarding of clear alarms is enabled, so notification-level alarms will also be forwarded.


Solution

On the alarm parameter configuration page, change clear alarm auto-forwarding to No