Issue of CPLD version changing to 3.0 after replacing the main control spare part for firewall F5000-CN30-D

  • 0 Followed
  • 0Collected ,128Browsed

Network Topology

Not involved

Problem Description

Replace the MPU. After replacement, it was found that the CPLD version of the new MPU does not match that of the old MPU on the device.

 

Process Analysis

The CPLD version is factory-burned into the hardware (HW)

It is irrelevant to the version and requires no attention

Solution

No need to follow

Please rate this case:   
0 Comments

No Comments

Add Comments: