R5500 G6-fan light not on

2025-06-25 11:30:02 Published
  • 0 Followed
  • 0Collected ,1Browsed

Problem Description

Customer feedback Fan6 fan light not working. After replacing the fan, the issue was found to follow the slot.

Process Analysis

R5500 G6 fan 1-15 control (Ctl) signal topology, where fan 6-15 are directly connected to the SW board CPLD via 0404A1YT All-in-one cable, then to each fan.

The control (Ctl) signals for fan 1-5 are routed through the gold finger to the mainboard, then to the SW board CPLD via 0404A1QM All-in-one cable, and finally to each fan.

Solution

In this case the issue was resolved by replacing the sw and 0404A1YT All-in-one cable

Please rate this case:   
0 Comments

No Comments

Add Comments: