I.        Product Model

H3C Uniserver G3&G5 Server

Involved Version

HDM 1.30.XX, HDM 2.XX, and versions before HDM 3.49.01 (exclusive)

Problem Description

H3C Uniserver G3 & G5 servers are experiencing issues with SDS log collection failures, repeated HDM restarts, and intermittent inaccessibility.

Cause Analysis

HDM earlier versions generated a large volume of logs, which could easily cause read/write anomalies in the log storage chip during long-term operation, thereby probabilistically triggering an HDM restart.

Note: An HDM restart does not affect the application system or data.

Workaround/Solutions

Upgrade to HDM version 3.49.01 or later.

Note: Manually restart HDM through the HDM interface or power cycle the server. Immediately after HDM restarts, perform the HDM firmware upgrade.