Early Warning |
|
|
Operational requirements |
Learning prevention, version upgrades, firmware upgrades |
I. Product Model
H3C UniServer G7 full product range
H3C UniStor Polaris X20000H
H3C UniStor Polaris X20000
All versions of the HDM3-2.xx series below HDM3-2.16.02 (not included) have this issue.
All versions of the HDM3-3.xx series below HDM3-3.06 (not included) have this issue.
HDM low-probability false alarm for PMC array card Battery failed; the alarm automatically clears shortly after being triggered.
RAIDx_Super_Cap/Battery Battery failed---PCIeslot:x

Array card battery fault alarm reporting mechanism: The array card firmware pushes the fault information to the BMC, The BMC converts and generates SEL logs, then synchronizes and reports them to the HDM Web interface.
After this alarm is triggered, it will be automatically cleared in the next polling cycle. Analysis has determined that it was a false alarm triggered by the array card firmware, and the solution is to add debounce logic on the BMC side to avoid such false reports.
2. If you are currently using HDM3-3.xx, it is recommended to upgrade to HDM3-3.06 or later versions.