Technical Announcement on the Issue of Dedicated Hot Spare Not Taking Effect When Setting RAID10/50/60 via HDM on Uniserver G3/G5 Servers

2026-09-04 15:40:18 Published
  • 0 Followed
  • 0Collected ,10Browsed

Product Model

Announcement category

Early Warning

Operational requirements

Learn prevention and security hardening

Servers with G3/G5 configurations and LSI RAID controllers


Involved Version

HDM B05 2.85 (inclusive) to 3.67 (exclusive)

HDM B06 versions prior to 6.25 (exclusive)

Problem Description

When setting a hot spare drive for RAID10 via the HDM interface on an LSI RAID controller, if a member drive in the RAID10 fails, the hot spare drive cannot participate in the rebuild. However, when setting the hot spare drive for RAID10 via BIOS or the OS, the hot spare drive can participate in the rebuild if a member drive fails.

Cause Analysis

Workaround/Solutions

(1) Workaround

Change the dedicated hot spare to a global hot spare in the HDM interface, or delete the dedicated hot spare and re-add it via BIOS or the OS.

(2) Resolution

Upgrade the HDM version to 3.67/6.25 (inclusive) or later, and then delete and re-add the dedicated hot spare in the HDM interface. 