Announcement category |
Early Warning |
|
Operational requirements |
Learn prevention and security hardening |
Servers with G3/G5 configurations and LSI RAID controllers
When setting a hot spare drive for RAID10 via the HDM interface on an LSI RAID controller, if a member drive in the RAID10 fails, the hot spare drive cannot participate in the rebuild. However, when setting the hot spare drive for RAID10 via BIOS or the OS, the hot spare drive can participate in the rebuild if a member drive fails.
Change the dedicated hot spare to a global hot spare in the HDM interface, or delete the dedicated hot spare and re-add it via BIOS or the OS.
(2) Resolution
Upgrade the HDM version to 3.67/6.25 (inclusive) or later, and then delete and re-add the dedicated hot spare in the HDM interface.