AC1 license count: 1024 | AC2 license count: 2261 | Shared group total: 3285
Dual AC license shared group remains continuously online, with no disruption.
On-site feedback: APs are offline, all due to License insufficient.
Alarm key screenshot:

1. Check that the remaining AC license is sufficient.
Total number of APs: 2524
Total number of connected APs: 2457
Maximum supported APs: 3584
Remaining APs: 1127
Total AP licenses: 3285
Local AP licenses: 3285
Remaining local AP licenses: 861
Sync AP licenses: 1024
Total number of APs: 3481
Total number of connected APs: 3416
Maximum supported APs: 3584
Remaining APs: 168
Total AP licenses: 3285
Local AP licenses: 3285
Remaining local AP licenses: 2304.50
Sync AP licenses: 2261
2. Look at AP distribution: AC1 has 2457 APs online (mixed R/M + R/B), AC2 has 3416 APs online.
3. Check AP uniqueness: after deduplicating by serial number, the globally unique online AP count = 3418, which already exceeds the total license sync group quota of 3285.
4. Check kick reasons: the remaining APs, during repeated attempts to come online on both sides, were kicked off by their respective ACs due to "insufficient license".